LG AIR CONDITIONER INSTALLATION MANUAL Pdf Download. Air Conditioner INSTALLATION MANUAL IMPORTANT Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference. Be careful when picking up and moving the indoor and outdoor units. Get a partner to help, and bend your knees when lifting to reduce strain on your back. Sharp edges or thin aluminum fins on the air conditioner can cut your finger. When installing. Air Conditioner Installation Manual CONTENTS Safety Precautions. Installation of Indoor, Outdoor unit. The indoor unit installation. Remote controller installation. Wiring connection. Flaring Work and Connection of Piping. Installation to decorative panel. Indoor unit drain piping. Test running. To prevent the injury of the user or other people and property damage, the following instructions must be followed. Be sure to read before installing the air conditioner. Be sure to observe the cautions specified here as they include important items related to safety. Safety Precautions Do not install the product at a place that there Use caution when unpacking and installing. Otherwise, it may result in personal injury. Sharp edges may cause injury. Operation Do not share the outlet with Do not use the damaged Do not modify or extend the other appliances. Buy Goodman GSX130301 Today. Free Shipping. TaxFree. Check the Goodman GSX13 2. Ton Air Conditioner 13 Nominal SEER SingleStage R410a Refrigerant. Indoor unit faults Fascia LEDs RED Fascia LEDs GREEN Contents Case of Error Indoor Status CH01 or C1 None 1 Flash Indoor Air Sensor OpenShort Open or. Floor Standing Type Air Conditioner Daikin India, one of the leading Air Conditioner Companies in India, Manufactures Floor Standing type Air Conditioning Systems. Use a soft cloth to clean. Do not use wax, ventilation sometimes. Otherwise, it may do harm to your health. The appearance of the air conditioner may deteriorate, change color, or develop surface flaws. Do not use an appliance for special purposes. Installation of Indoor, Outdoor Unit Installation of Indoor, Outdoor Unit Selection of the best location 1. Indoor unit Cassette type There should not be any heat source or steam near the unit. There should not be any obstacles to prevent the air circulation. Do not place animals and plants in the path of the warm air. Take the air conditioner weight into account and select a place where noise and vibration are minimum. Installation of Indoor, Outdoor Unit 3. Piping length and the elevation Pipe Size Length A Elevation B Additional Capacity Unit mminch Unit mft Unit mft refrigerant Unit gmozft Liquid Standard Max. Standard Max. 5. 01. Btuh 1. 5. 8. 858 Make sure that ventilation fan is enough to cover all noxious gases from this place. Ensure enough distance from the cooking room to install the air conditioner in such a place where it may not suck oily steam. W38 or M1. Ceiling board Ceiling board Spring washer M1. Keep the length of 1. Flat washer for M1. Set screw of paper model 4 pieces W38 or M1. The hole should be sightly slant to the outdoor side. Insert the plastic tube through the hole. Tilt 4. Cut the extruded outside part of the plastic Cut if necessary tube, if necessary. More than 1. 5mm0. Air Conditioner. Remote controller installation Remote controller installation Wired remote controller installation Since the room temperature sensor is in the remote controller, the remote controller box should be installed in a place away from direct sunlight, high humidity and direct supply of cold air to maintain proper space temperature. And when you pull the driver in the front direction, the wired remote controller will be separated. Air Conditioner. Remote controller installation 5. Use the connecting cable to connect the indoor unit and the wired remote controller. Check whether the connector is connected correctly. Indoor unit side Connecting cable 6. When the distance between the wired remote controller and the indoor unit is 1. ETL recognized and CSA certified. RECOMMENDATION When using the separate wires as the power cord, please secure the separate wires into the control box panel using tie wraps to hold all wires together in place. Air Conditioner. Open the Control Box Cover A with Driver, as shown in Fig. Connect the Cables LG doesnt supply to the terminal Block of Indoor Unit, as shown in Fig. Install a power supply line or connecting cables as the Fig. Wiring Connection Fig. CapRemove 1. 8 Air Conditioner. All wiring must comply with LOCAL REGULATIONS. Select a power source that is capable of supplying the current required by the air conditioner. Feed the power source to the unit via a distribution switch board designed for this purpose. Connecting Cable round terminal. Position the round terminal wire, and replace Loosening the Fastening the and tighten the terminal screw using a terminal block wire tightly screw screwdriver. Connecting cable 2. Air Conditioner. Flaring Work and Connection of Piping Flaring Work and Connection of Piping Flaring work Main cause of gas leakage is defect in flaring work. Carry out correct flaring work in the Copper Slanted Uneven Rough tube following procedure. Cut the pipes and the cable. Use the accessory piping kit or the pipes purchased locally. Union gas side valves. CAUTION Use two wrenches and tighten with regular torque. Outside diameter torque kgf. Air Conditioner. Installation to Decorative Panel Installation to Decorative Panel The decorative panel has its installation direction. Before installing the decorative panel, always remove the paper template. Remove the packing and take out air inlet grille from front panel. Front grille 2. The position marking on PCB is as Display connector CN DISPLAY Vane control connector CN VANE 1,2 CN VANE 1,2 CN DISPLAY 8. Xem Phim Suc Manh Tinh Than Tap 18 Ho here. Close the cover for control box. Install the air inlet grille and Filter on the panel. Air Conditioner. Indoor Unit Drain Piping CAUTION Install certainly the decorative panel. Cool air leakage causes sweating. Water drops fall. Good example Bad example Air conditioner unit Air conditioner Cool air leakage unit no good Ceiling Ceiling board board Decorative Decorative panel. Drain test The air conditioner uses a drain pump to drain water. Use the following procedure to test the drain pump operation Connect the main drain pipe to the exterior and. C2. 48F. Fastening band 2. Precautions in high humidity accessory circumstance This air conditioner has been tested according to the KS Standard Conditions with Mist and confirmed that Refrigerant piping there is not any default. However, if it is. When installing on the wall, roof or rooftop, anchor the mounting base securely with a nail or wire assuming the influence of wind and earthquake. If the vibration of the unit is transmitted to the hose, secure the unit with an anti vibration rubber. Air Conditioner. PRECAUTIONS IN TEST RUNNING The initial power supply must provide at least 9. Otherwise, the air conditioner should not be operated. CAUTION For test run, carry out the cooling operation firstly even during heating season. In case of duct type, the Airflow UPDOWN function is not displayed. During test run mode, receiving signal from wireless remote controller will release this operation. If you press any kind of button, Test Run mode will be released. Air Conditioner. N After the confirmation of the above conditions, prepare the wiring as follows 1 Never fail to have an individual power specialized for the air conditioner. As for the method of wiring, be guided by the circuit diagram pasted on the inside of control box cover. Usually, the cylinder is used in a vertical standing position.